ISSN 1673-8217 CN 41-1388/TE
Supervisor:China Petrochemical Corporation Limited Sponsor:Sinopec Henan Oilfield Company
Shi Qingdong, . 1999: A Discussion Errors Caused by Treating Transmitter Coil as Point Magnetic Dipole in A. C. Electric Logging. Petroleum Geology and Engineering, 13(05): 24-25+28-60.
Citation: Shi Qingdong, . 1999: A Discussion Errors Caused by Treating Transmitter Coil as Point Magnetic Dipole in A. C. Electric Logging. Petroleum Geology and Engineering, 13(05): 24-25+28-60.

A Discussion Errors Caused by Treating Transmitter Coil as Point Magnetic Dipole in A. C. Electric Logging

  • This paper presents the deducing procedures and formulations of rigorous solutions and approximate solutions (i. e. when taking transmitter coil as point magnetic dipole) of induction voltage of dual coil in homogeneous medium. Relative errors of amplitude ratio and phase shift caused by the approximation are calculated by taking a simple radio-frequency logging tool as an example. Other conventional A.C. (alternatingcurrent) logging tools are studied with the same method.Study results show that, as to conventional logging tools,this kind of errors can be ignored.
  • loading

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return